APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22460 Issued:2023-03-03
Revised:2023-03-23
Style 22460 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 90 Vac Cable flame.
Conductor50 AWG - 10 AWG, Solid or stranded.
InsulationLabeled or complying with the manufacturer's AWM Procedure.
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketTPU
Diameter of core assembly under jacket(inches)*Minimum average thickness(mils)Minimum thickness at any point(mils)
0 - 2.5001512
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring in Class 2 Circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024