APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22462 Issued:2023-03-21
Revised:2023-03-23
Style 22462 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal Flame.
Conductor40 AWG minimum solid or stranded
InsulationLabeled or Complying with manufacturer's AWM procedure.
AssemblyTwo or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May be use same or mixed AWG size.
CoveringOptional - A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
0.700 or less3024
0.701-1.0006048
1.001-1.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.