APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2247 Issued:1959-05-01
Revised:2012-07-27
Style 2247 Multiple-conductor cable using non-intregal jacket.

Rating80 deg C, 300 Vac, FT2 flame.
Conductor26 AWG - 16 AWG stranded round bare copper.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblySix conductors, same as type SJT.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances