APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22472 Issued:2023-07-12
Revised:New
Style 22472 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating105 deg C,-40 deg C,300 Vac, Cable flame, Sunlight Res (required).
Conductor22 AWG to 2 AWG, solid or stranded.
InsulationExtruded TPE, 5 mils minimum average thickness, 4 mils minimum thickness at any point.
AssemblyConsists of two D-shaped conductors and two round conductors. The conductors may be twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval, or round cable. The lay of the conductors is not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded TPE. See Facing Page for compound.
Diameter of Core Assembly under jacket in inchesMinimum average thickness (mils)Minimum thickness at any point (mils)
0.000-0.7003326
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.