APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2248 Issued:1959-05-01
Revised:2012-07-13
Style 2248 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor20 AWG stranded round.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblySeven conductors, same as type SJT.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024