APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22481 Issued:2023-08-25
Revised:2023-08-29
Style 22481 Multiconductor Cable with extruded non-integral jacket

Rating105 deg C,-40 deg C(Optional), 300 V, Sunlight Res (optional), Cable flame, VW-1, Horizontal Flame
InsulationLabeled or Complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
JacketPVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
*Sunlight Resistant PVC Jackets will be subjected to 720 h Weatherometer Exposure (see Facing Page for jacket compound)
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.