APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22482 Issued:2023-08-23
Revised:New
Style 22482 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating80 deg C, 600 Vac, Horizontal Flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldAL PETP Foil and Metal Coated Copper Braid
JacketExtruded FRPE, Minimum average thickness 26 mils, Minimum thickness at any point 21 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024