APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22484 Issued:2023-09-15
Revised:2023-09-18
Style 22484 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Horizontal Flame.
Conductor50 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or two or more conductors or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional, Extruded PVC, 13 mil minimum at any point or extruded TPE, 6 mil minimum at any point.
ShieldOptional.
JacketExtruded TPU
Diameter of cable under jacket in inchesminimum average thickness in milsminimum thickness at any point in mils
0.300 or less1512
0.301-0.4502217
0.451-0.5503024
0.551-0.8006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring in Class 2 Circuits.

UL and the UL Logo are trademarks of UL LLC © 2024