APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22485 Issued:2023-09-15
Revised:2023-09-18
Style 22485 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Cable Flame.
Conductor50 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or two or more conductors or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional, Extruded PVC, 13 mil minimum at any point or extruded TPE, 6 mil minimum at any point.
ShieldOptional.
JacketExtruded TPU
Diameter of cable under jacket in inchesminimum average thickness in milsminimum thickness at any point in mils
0.300 or less1512
0.301-0.4502217
0.451-0.5503024
0.551-0.8006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.