APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22486 Issued:2023-09-21
Revised:2023-10-16
Style 22486 Multiconductor Cable with Non-extruded Covering

Rating105 deg C,30 Vac Horizontal flame, VW-1 flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
Outer CoveringRequired. Two layers, Non-extruded PET tape with Polyester Adhesive, thickness 1 mil minimum average, 0.5 mil minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.