APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2249 Issued:1959-05-01
Revised:2012-04-17
Style 2249 Multiple Conductor with Extruded Insulation and Extruded Integral Jacket.

Rating80 deg C, 300 Vac, FT2 flame.
Conductor26 AWG - 16 AWG solid or stranded round.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblySeven conductors, same as type SJT.
JacketExtruded PVC, 30 mils min average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn appliances at temperatures not to exceed 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024