APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22492 Issued:2024-01-10
Revised:2024-01-02
Style 22492 Multiple-Conductor Cable Using Extruded non-Integral Jacket

Rating90 deg C, 90 Vac
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. Lay not specified. Barrier layer and/or binders, fillers optional. Manufacturer shall maintain a complete description of each assembly. Overall Cable may be either straight or coiled in the form of a helix.
ShieldOptional - copper braid
JacketExtruded FEP, 5mils minimum average thickness, 4mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025