APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2254 Issued:1959-05-01
Revised:2011-12-02
Style 2254 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationSame as for Type SVT Cord except using Thermoplastic (PVC) Compounds suitable for use at 80 C.
AssemblySix conductors, same as type SVT. A cotton serve is provided over the assembly.
JacketSame as for Type SVT Cord except using Thermoplastic (PVC) Compound suitable for use at 80 C.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn thermal massagers where exposed to temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024