APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22541 Issued:2024-08-16
Revised:2024-08-20
Style 22541 Multiple-conductor cable using non-integral jacket

Rating90 deg C, 1000 Vac, Cable Flame.
Conductor40 AWG min. solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of one or more conductors or groups of conductors twisted together. The conductors or groups of conductors may be laid to form anoval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
BraidOptional. Copper tinned or bare, with minimum coverage of percent.
JacketExtruded TPE
Dia of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 in or less30 mils24 mils
0.701-1.000 in45 mils36 mils
1.010-1.500 in60 mils48 mils
1.501-2.500 in80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring or Internal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025