Rating | 105 deg C,30 Vac, Horizontal flame, VW-1. |
|
Conductor | 30 AWG - 20 AWG, Solid or Stranded |
|
Assembly | Two (2) insulated conductors twisted or laid parallel with inner covering, shield and outer covering, all as described below. |
|
Insulation | Extruded FEP with minimum average thickness 4 mils, minimum thickness at any point 3.5 mils. |
|
Inner Covering | Non-extruded PTFE tape with 2 mils minimum thickness provided over the pair of insulated conductors. |
|
Shield | An Al/PP, AL/PET, Cu/PP, or Cu/PET shield with 2 mils minimum thickness shall be provided over the inner covering. |
|
Outer Covering | Two Non-Extruded Polyimide Kapton Tapes with EVA adhesive, provided over the shield. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|