APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22548 Issued:2024-10-18
Revised:2024-10-16
Style 22548 Multi-Conductor Cable with Non-extruded Covering

Rating105 deg C,30 Vac Horizontal flame.
Conductor50 AWG - 2000 kcmil, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Inner CoveringOptional.
ShieldOptional.
Outer CoveringRequired, Non-extruded Heat-Sealed PET tape, 1 mil minimum average thickness, 0.8 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025