APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2255 Issued:1959-05-01
Revised:2012-04-12
Style 2255 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point.
AssemblySeven conductors, same as type SVT. A cotton serve is provided over the assembly.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn thermal massagers where exposed to temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024