APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2257
Issued:
1959-05-01
Revised:
2008-05-27
Style
2257
SJT cord.
Rating
60 deg C, 300 Vac, FT2 flame.
Conductor
18 AWG - 10 AWG stranded round, tinned or bare copper.
Insulation
PVC, 30 mils min average, 27 mils minimum at any point.
Assembly
Five conductors, same as type SJT.
Jacket
PVC, 30 mils min average, 24 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
In couches or hospital beds and internal wiring of electric lawn mowers or X-ray equipment, or External Interconnection of Vending Machines and Appliances, or internal wiring of mobile home air Conditioners.