Flat cable.
Rating
60 deg C, 600 Vac, FT2 flame.
Conductor
Three coaxial cables No. 22 AWG (7 strands No. 30 AWG tinned copper.) Eight No. 22 AWG (7 strands No. 30 AWG tinned copper) Two No. 20 AWG (7 strands No. 28 AWG tinned copper) Two No. 18 AWG (41 strands No. 34 AWG bare copper) See Facing Page for Arrangement of Conductors.
Insulation
On all but coaxial cables insulation shall be a nominal 30 mil wall PVC. Two of the coaxial cables shall have a 60 mil wall polyethylene and the third a 45 mil wall polyethylene. The coaxial cables shall be provided with a spiral wrap shield of tinned copper strands and jacketed with a 30 mil wall of PVC.
Assembly
Fifteen conductors. Four ropes of twisted conductors (see facing page) and the three coaxial cables shall be laid parallel and the jacket applied overall. Maximum finished cable size shall be 1.75 inch by 0.355 in.
Shield
Optional.
Jacket
PVC, 30 mils min average, 24 mils minimum at any point. The surface of the jacket shall be smooth and free of ridges, valleys and other imperfections.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
For use as Remote Control Cable on Television Receivers.