APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2267 Issued:1959-05-01
Revised:2012-07-25
Style 2267 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded PVC, 15 mils min average, 14 mils minimum at any point.
AssemblyFour conductors.
ShieldOver one or more insulated conductors. Shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point or lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.