Style 2276 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor26 AWG - 16 AWG stranded round.
InsulationExtruded PVC, 15 mils min average, 14 mils minimum at any point.
AssemblySeven conductors, same as type SVT. Different conductor sizes may be employed in one cord.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.