APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2285 Issued:1959-05-01
Revised:2012-02-27
Style 2285 Multiple-conductor cable with extruded insulation and non-integral jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor26 AWG - 16 AWG, stranded round, tinned or bare copper.
InsulationExtruded PVC, 15 mils minimum average, 13 mils minimum at any point.
AssemblySixteen conductors, same as Type SVT. Different conductor sizes may be employed in one cord.
JacketExtruded PVC, 30 mils minimum average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseOnly in the internal wiring of X-Ray Equipment; or, in the internal wiring of electronic equipment.