Subj.758 Section 2 Page 2286 Issued:1959-05-01
Revised:2013-02-07
Style 2286 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, FT2 flame.
Conductor26 AWG - 16 AWG, stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblySeventeen conductors, different conductor sizes may be employed in one cord.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of X-Ray Equipment or internal wiring of electronic equipment.