Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 22 AWG, 16 AWG, each consisting of No. 30 AWG or smaller tinned copper strands. |
|
Insulation | Extruded PVC, 15 mils minimum average thickness, 14 mils minimum thickness at any point. |
|
Assembly | Five conductors, A, B, and C No. 22 AWG, D and E No. 16 AWG, same as type SJT. A, B, and C shall have a nominal 15 mil wall, D and E shall have a nominal 30 mil wall, otherwise same as Type SJT Cord. All conductors shall be provided with a lacquered provided with a copper braid shield (six No. 40 AWG strands in each of sixteen carriers, eighteen picks per inch). The conductors shall be combined with cotton or jute fillers and twisted together with a 3-1/2 inch max. right-hand lay. A cotton serve shall be applied over the conductor assembly. |
|
Jacket | Extruded PVC, 60 mils minimum average thickness, 48 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|