This Style Page is no longer being updated. It is for historic reference only. Please visit: Search - Appliance Wiring Material - Company - Product iQ for the latest Style Page information 
Subj.758 Section 2 Page 2292 Issued:1959-05-01
Revised:2013-01-30
Style 2292 Multiconductor cable with extruded non-integral jacket

Rating80 deg C, 300 Vac, FT2 flame.
ConductorConductors A, B, C and D, 22 AWG. Conductors E, F, G and H, 20 AWG. Stranding not larger than 30 AWG.
InsulationExtruded PVC. For conductors A-D, 15 mils minimum average thickness, 13 mils minimum thickness at any point. For conductors E-H, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyEight conductors cabled uniformly round. Jute center filler and binder threads over core optional. Valleys between conductors may show through jacket.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs an interconnecting cable.

UL and the UL Logo are trademarks of UL LLC © 2026