APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2294 Issued:1959-07-17
Revised:2012-06-29
Style 2294 Two conductor SPT-3 style Cord.

Rating105 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor18 or 16 AWG consisting of No. 30 AWG or smaller copper strands.
InsulationIntegral with Jacket. PVC, 60 mils min average, 54 mils minimum at any point.
AssemblyTwo conductors, same as type SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where exposed to temperatures not exceeding 105 deg C; or Internal wiring of electric refrigerators where exposed to temperature not exceeding 105 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 105 deg C or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 105 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024