APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2296 Issued:1959-07-17
Revised:2012-07-01
Style 2296 Parallel cable with extruded integral insulation and jacket.

Rating105 deg C, 300 Vac, FT2 flame, Optional - Oil Resistant 60 deg C or 80 deg C.
Conductor18 or 16 AWG consisting of No. 30 AWG or smaller strands.
InsulationExtruded integral PVC insulation and jacket, 60 mils min average, 54 mils minimum at any point.
AssemblyTwo conductors, same as type SPT-2; except for a nominal 60 mil, the following minimum (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where ripped not more than three inches and where exposed to temperatures not exceeding 105 deg C; or wiring of Butter Conditioners where exposed at the door hinge at a temperature not exceeding 105 deg C. Either marking may also add where applicable dependent upon the compound use; and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.