APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2297 Issued:1959-07-17
Revised:2011-10-10
Style 2297 Parallel cable with extruded integral insulation.

Rating105 deg C, 300 Vac, FT-2 Flame, Optional - 60 deg C or 80 deg C Oil Resistant.
Conductor18 or 16 AWG, stranded, consists of 30 AWG or smaller conductor strands.
InsulationExtruded PVC, 60 mils minimum average thickness. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.058 inch, Web thickness: 0.078 inch, Wall after rip: 0.028 inch.
AssemblyThree-conductor, same as flexible cord type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where ripped not more than three inches and where exposed to temperatures not exceeding 105 deg C; or Internal wiring of butter conditioners where exposed at the door hinge at a temperature not exceeding 105 deg C. Either marking may also add where applicable dependent upon the compound use; and where exposed to oil at a temperature not exceeding 60 deg C or 80 deg C; whichever is applicable. Polarity identification may be omitted.