APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2298 Issued:1959-07-17
Revised:2011-09-30
Style 2298 SPT-3 Cord.

Rating105 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor14, 12, or 10 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationIntegral with Jacket. PVC, 70 mils min average, 63 mils minimum at any point.
AssemblyTwo conductors, same as type SPT-3; except for a nominal 80 mil, the following minimum (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.109 in., Wall after rip: 0.043 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units where ripped not more than three inches and where exposed to temperatures not exceeding 105 deg C; or Internal Wiring of Remote Outdoor Condensing units for Domestic Cooling Systems where exposed to temperatures not exceeding 105 deg C. Either marking may also add where applicable dependent upon the compound use: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C; whichever is applicable). Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024