APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2300 Issued:1959-07-17
Revised:2012-03-29
Style 2300 Parallel Cable with extruded integral insulation

Rating105 deg C, 300 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor18 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationPVC, 28 mils min average thickness, 25 mils minimum thickness at any point.
AssemblyTwo conductors, same as type SPT-1; Except for a nominal 80 mils seperation between conductors, the following minimum dimensions shall apply: Wall thickness: 0.028 in., Web thickness: 0.080 in., Wall after rip: 0.028 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet, and where exposed to temperatures not exceeding 105 deg C. Dependent upon the compound used, the tag may add the statement: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.