APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2307 Issued:1960-01-05
Revised:2012-04-17
Style 2307 Multiple Conductor with Extruded Insulation and Extruded Internal Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor22 AWG, 18 AWG, each consisting of No. 30 AWG strands.
InsulationPVC, 30 mils min average, 27 mils minimum at any point.
AssemblyFive conductors A and B, No. 22 AWG, C No. 16 AWG, D and E No. 18 AWG ; A, B, D, and E same as for Type SJT cord;C - bare. A, B, and C twisted together with fillers in a 1-in. lay with an outerwrap of conductive cotton yarn. The above subassembly cabled with D and E and fillers in a 3.5-in. lay. A paper wrap is applied over the conductor assembly.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use with electric organs.