APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2310 Issued:1960-05-10
Revised:2013-01-30
Style 2310 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor22 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo conductors.
ShieldA conductive thermoplastic material 7 mils nominal thickness, 6 mils minimum wall thickness at any point, in conjunction with a 20 or 22 AWG, stranded or solid, tinned or bare bonding conductor. The shield may also be a wrap of aluminum faced "Polyester" tape with a parallel uninsulated drain wire. The shield may be applied over one or both conductors.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. The color of the jacket shall be other than black.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.