APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2311 Issued:1960-05-10
Revised:2012-03-08
Style 2311 Multi-conductor Cable using Non-Integral Jacket.

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE or extruded FRPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo insulated conductor.
ShieldA conductive thermoplastic material 7-mils nominal, 6-mils minimum wall, in conjunction with a 20 or 22 AWG. stranded or solid, tinned or bare copper bonding conductor. Shielding may also be a wrap of aluminum faced polyester tape with a parallel uninsulated drain wire.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. The color of the jacket shall be other than black.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-up and Volume Control; or In Internal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024