APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2313 Issued:1960-05-31
Revised:2012-04-18
Style 2313 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, stranded.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyFive conductors, same as Type SJT.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024