APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2317 Issued:1960-08-30
Revised:2011-09-09
Style 2317 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round.
InsulationExtruded PE, 31 mils minimum average, 28 mils minimum at any point.
AssemblyTwo conductors. Fillers (optional).
ShieldMetal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced Polyester with drain wire. Uninsulated drain wire optional where not specified.
JacketExtruded PVC, 31 mils minimum average, 23 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.
UsePhonograph Pick-up and Volume Control; or in the Internal Wiring of Appliances. .