APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2322 Issued:1960-11-23
Revised:2012-07-11
Style 2322 Multiconductor with Extruded Insulated Singles and Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
ConductorFive to Ten Conductors, No. 18 or 20 AWG employing individual copper strands of No. 36 AWG. 65/No. 36 or 41/No. 36, respectively.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblyFive to ten conductors, similar to Type SJT in UL62.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or Internal Wiring for couches and hospital beds.

UL and the UL Logo are trademarks of UL LLC © 2024