APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2323 Issued:1960-12-14
Revised:2012-07-03
Style 2323 Multiple Conductor with Extruded Insulation and Extruded Jacket.

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor22 AWG - 20 AWG.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thoickness at any point. Six conductors provided with nominal 15 mil wall and two conductors provided with nominal 30 mil wall.
AssemblyEight conductors. Twisted together with a maximum lay of 4 inches. Fillers are optional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseTelevision remote control cable where the acceptability of the combination has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024