APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2325 Issued:1960-12-27
Revised:2012-07-05
Style 2325 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating90 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round.
InsulationExtruded PVC, 31 mils min average, 28 mils minimum at any point.
AssemblyTwo conductors.
ShieldMetal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced Polyester with drain wire. Uninsulated drain wire optional where not specified.
JacketExtruded PVC, 31 mils min average, 25 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024