Rating | 90 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 26 AWG - 16 AWG solid or stranded round. |
|
Insulation | Extruded PVC, 31 mils min average, 28 mils minimum at any point. |
|
Assembly | Two conductors. |
|
Shield | Metal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced Polyester with drain wire. Uninsulated drain wire optional where not specified. |
|
Jacket | Extruded PVC, 31 mils min average, 25 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less. |
|
Use | Internal wiring. |
|