Rating | 105 deg C, 600 Vac, FT-2 flame, Moisture Res 60 deg C |
|
Conductor | 14, 12, or 10 AWG consisting of 30 AWG or smaller tinned or bare copper. |
|
Insulation | Integral with Jacket. PVC, 70 mils min average, 63 mils minimum at any point. |
|
Assembly | Two conductors.Same as for Type SPT-3, except for a nominal 80 mil wall, the following minimum (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.141 in., Wall after rip: 0.058 in.. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electric Refrigerating Equipment or Room Air Conditioners or Room Cooler Units where exposed to temperatures not exceeding 105 deg C; or Internal Wiring of Electric Refrigeration Equipment or Room Air Conditioners of Room Cooler Units where exposed to temperatures not exceeding 105 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); Moisture Resistant 60 deg C. Polarity identification may be omitted. |
|