APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2327 Issued:1961-06-15
Revised:2012-03-22
Style 2327 Parallel cable with extruded integral insulation and jacket

Rating105 deg C, 600 Vac, FT-2 flame, Moisture Res 60 deg C
Conductor14, 12, or 10 AWG consisting of 30 AWG or smaller tinned or bare copper.
InsulationIntegral with Jacket. PVC, 70 mils min average, 63 mils minimum at any point.
AssemblyTwo conductors.Same as for Type SPT-3, except for a nominal 80 mil wall, the following minimum (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.141 in., Wall after rip: 0.058 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerating Equipment or Room Air Conditioners or Room Cooler Units where exposed to temperatures not exceeding 105 deg C; or Internal Wiring of Electric Refrigeration Equipment or Room Air Conditioners of Room Cooler Units where exposed to temperatures not exceeding 105 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); Moisture Resistant 60 deg C. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024