APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2329 Issued:1961-06-15
Revised:2012-02-09
Style 2329 Parallel cable with extruded integral insulation and jacket.

Rating105 deg C, 600 Vac, FT2 flame, Oil Res 60 deg C or 80 deg C (optional), Moisture Res 60 deg C
Conductor18 or 16 AWG consisting of 30 AWG or smaller tinned or bare copper.
InsulationIntegral with Jacket. Extruded PVC, 58 mils min average, 52 mils minimum at any point.
AssemblyTwo conductors, same as type SP-3; except for a nominal 60 mil wall, the following minimum (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.141 in., Wall after rip: 0.058 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators or Room Cooler Units where ripped not more than 15 inches and where exposed to temperatures not exceeding 105 deg C. Tag may also add: where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); Moisture Resistant, 60 deg C. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024