APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2330 Issued:1961-06-15
Revised:2011-09-28
Style 2330 Parallel cable with extruded integral insulation and jacket.

Rating105 deg C, 600 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (opt), Moisture Resist 60 deg C
Conductor18 or 16 AWG consisting of 30 AWG or smaller tinned or bare copper.
InsulationIntegral with Jacket. PVC, 60 mils min average, 54 mils minimum at any point.
AssemblyThree conductors. Same as for Type SPT-3, except for a nominal 60 mil wall, the following minimum (pin gauge) dimensions: Wall thickness: 0.058 in., Web thickness: 0.141 in., Wall after rip: 0.058 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators or Room Cooler Units where ripped not more than 15 inches and where exposed to temperatures not exceeding 105 deg C. Tag may also add: where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); Moisture Resistant, 60 deg C. Polarity identification may be omitted.