Rating | 105 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional). |
|
Conductor | 18 AWG - 16 AWG consisting of 30 AWG or smaller strands. |
|
Insulation | Integral with Jacket. PVC, 60 mils min average, 54 mils minimum at any point. |
|
Assembly | Three conductors, same as type SPT. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electric refrigerators where exposed to temperature not exceeding 105 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 105 deg C, or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted. |
|