APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2334 Issued:1961-09-14
Revised:2012-06-29
Style 2334 SPT-3 Cord.

Rating105 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor18 AWG - 16 AWG consisting of 30 AWG or smaller strands.
InsulationIntegral with Jacket. PVC, 60 mils min average, 54 mils minimum at any point.
AssemblyThree conductors, same as type SPT.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where exposed to temperature not exceeding 105 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable); or Internal wiring of gas or oil-fired domestic heating equipment where exposed to temperature not exceeding 105 deg C, or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024