APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2335 Issued:1961-09-15
Revised:2012-03-12
Style 2335 Multiple-conductor using non-integral jacket.

Rating80 deg C,Voltage not specified, Horizontal flame.
Conductor32 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 8 mils min average, 6 mils minimum at any point.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size.
CoveringOptional. Extruded PVC, a 6 mils or heavier, may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC.
Dia. of cable under jacket in inchesAverage thickness in milsMinimum thickness at any point in mils
0.350 or less1512
0.351-0.7003024
0.701-1.0004536
1.001-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.