Rating | 80 deg C,Voltage not specified, Horizontal flame. |
|
Conductor | 32 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded PVC, 8 mils min average, 6 mils minimum at any point. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. |
|
Covering | Optional. Extruded PVC, a 6 mils or heavier, may be extruded over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Dia. of cable under jacket in inches | Average thickness in mils | Minimum thickness at any point in mils |
| 0.350 or less | 15 | 12 |
| 0.351-0.700 | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|