APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2339 Issued:1962-05-17
Revised:2012-03-09
Style 2339 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 300 Vac (Jacket), 600 Vac (Insulation), Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo to twelve conductors.
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.