APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2340 Issued:1962-06-11
Revised:2012-07-26
Style 2340 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor18 AWG stranded, each consisting of 30 AWG strands.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point. A, B, C, and D 30 mil wall, Style 1011; E and F 15 mil wall, Style 1007.
AssemblySix conductors. Conductors A, B, C, and D twisted together around core with fillers in a 5 inches lay with cotton serving. Conductors E and F twisted together for core in a 1 inch lay. Style 1011 for Conductors A, B, C, and D; Style 1007 for Conductors E and F.
FillerCotton.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use with Electric Organs.

UL and the UL Logo are trademarks of UL LLC © 2024