| Rating | 80 deg C, Voltage not specified, Cable flame. |
|
| Conductor | Minimum 30 AWG, stranded. |
|
| Insulation | Labeled or complying with manufacturer's AWM Procedure and having a minimum temperature of 80°C.
|
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
|
|
| Covering | Optional - Extruded PVC, 6 mils minimum average thickness, may be applied over the conductor assembly. |
|
| Shield | Optional. |
|
| Jacket | Extruded PVC |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 2.50l and larger | 140 mils | 112 mils |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | External interconnection of computers and electronic equipment. |
|