APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2346 Issued:1962-09-24
Revised:2012-01-30
Style 2346 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, Voltage not specified, Cable flame.
ConductorMinimum 30 AWG, stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure and having a minimum temperature of 80°C.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional - Extruded PVC, 6 mils minimum average thickness, may be applied over the conductor assembly.
ShieldOptional.
JacketExtruded PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
2.50l and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of computers and electronic equipment.