APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2349 Issued:1962-12-20
Revised:2011-12-02
Style 2349 Multiple-conductor cable using non-integral jacket.

Rating60, 90 deg C, 300 Vac, 600 Vdc, Horizontal flame.
Conductor24 AWG - 16 AWG, solid or stranded.
InsulationLabeled styles as follows; Number 1, 24 AWG, Style 1118, with shield of 38 AWG strands and jacket; Numbers 2 to 5: 18 AWG, Style 1013; Numbers 6 to 7: 16 AWG, Style 1013; Numbers 8 to 14: 22 AWG, Style 1013.
AssemblyFourteen conductors cabled into a round cable with 3-1/2 in. max lay. Fillers or wraps optional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn wiring of electric organs.

UL and the UL Logo are trademarks of UL LLC © 2024