This Style Page is no longer being updated. It is for historic reference only. Please visit: Search - Appliance Wiring Material - Company - Product iQ for the latest Style Page information 
Subj.758 Section 2 Page 2350 Issued:1963-01-11
Revised:2011-11-24
Style 2350 Multiconductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 300 Vac (jacket), 600 Vac (Insulation), Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyThree conductors.
ShieldOver one or more insulated conductors. Shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point or lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.