APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2359 Issued:1963-05-17
Revised:2012-04-03
Style 2359 Parallel cable with extruded integral insulation and jacket.

Rating60 deg C, 300 Vac, FT2.
Conductor24 AWG - 16 AWG, solid or stranded. AWG may be varied within cord
Integral Insulation and JacketExtruded PVC, 30 mils min average, 27 mils minimum at any point. Same as for Type SPT-1.
AssemblyTwo to seven conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn electric bedding.

UL and the UL Logo are trademarks of UL LLC © 2024