APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2362 Issued:1963-05-24
Revised:2012-07-11
Style 2362 Parallel Cable with Integral Insulation and Jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorTwo Conductors, No. 28 AWG - 18 AWG solid or stranded round.
Integral Insulation and JacketExtruded PVC, 15 mils min average, 13 mils minimum at any point.
AssemblyTwo conductors, same as type SPT in UL62, except the insulation is nominal 15 mils thick and shall maintain at least 13 mils of thickness after ripping at the web.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024